version 11

Download Version 11 for VR9500
Download Version 11 for VR8500

New Features in Version 11.0

Here are the highlighted features included with version 11.0.

Tablet control

Web & Tablet Control

Updated web interface with added tablet-based remote control capability

128 channel

128 Input Channels

Now connect up to 128 input channels for control and response

version 11 phase tracking

Resonance Phase Tool

Ensure products with high-Q resonances track at the maximum amplitude

angular/rotary control

Angular/Rotary Control

Control rotary systems with angular acceleration control and response

DC control

Analog & DC Control

Simultaneous analog and DC control

64 bit native

Native 64-bit

Unicode support and 5 languages (Chinese, English, German, Japanese, Russian)

accelerometer calibration

Charge Type Calibration

Includes charge-type sensors in our Accelerometer Calibration Package (VR9106)

excel reporting

MS® Excel Reporting

We've added support for direct custom reporting to Microsoft Excel®





Remote Web and Tablet Control



We've updated our web interface feature by adding more control options and improved the users GUI.

web access

This update also provides support for the use of a tablet as a remote control device to get you closer to your test item during testing.



video: Instructions for using Remote Control

tablet control




128 Input Channels



Connect up to 128 channels for the those projects that require higher measurement or control channels. With an upgrade to version 11 current VR9500 users can also extend their channel count above 32 channels.

128 channels


high channel controller

















Need to control a second shaker?

As always, the VR9500 provides the ultimate in flexibility when you need to combine or separate to control more than one shaker.


Sine Phase Tracking Tool



New Controls to 'dial in' on a resonance and maintain peak amplitude by way of Phase vs Transmissibility. Enables tracking of High Q or sharp resonances.

VibrationView Screen

advanced srtd 1advsrtd

When a product begins to fatigue, the frequency values of its resonances will decrease, but its phase value for the resonance will not. Using the frequency-tracking SRTD method, when the product begins to fatigue the test will no longer be dwelling at the resonance of the product because that resonance value has changed. Using Advanced SRTD, the test will continue to maintain the same phase, but allow the frequency value to adjust with the changing resonant frequency of the product. Read the paper

Watch the Webinar

Watch our Advanced SRTD webinar.
Advanced SRTD is included standard with (VR9105) SRTD.


Angular Control



Configure your rotary system for angular unit control with angular system limits. Users can now directly enter a sensor radius when controlling by rotational/angular acceleration. VibrationVIEW will automatically re-calculate your shaker's limits based on that radius, and provide control in angular units.

angular control


video: See a rotary vibration table in action

rotary video
video (password protected): Rotary controls with VibrationVIEW


Analog & DC Control



Closed loop control of a DC signal, overlaid with a vibration profile enables you to control the shaker position based on displacement, pre-load a force, control the speed of a dyno machine, and more.


video: DC Control Loop Setup


Native 64-Bit



VibrationVIEW now available for native 64-bit operating systems. Includes unicode support.

laptop



Unicode Supports Multiple Languages

     
  • English
  • Chinese
  • German
  • Italian
  • Japanese
  • Russian
dc control 2

Download Version 11 for VR9500
Download Version 11 for VR8500


Charge-Type Calibration



We've now added charge-type sensor calibration cability to our Accelerometer Calibration Verification test software (VR9106). This software package can now calibrate both mV/g and pC/g sensors.


video: Charge-type sensor setup  


Native MS Excel Reporting

In addition to being able to report to MS® Word we can now also report to MS® Excel. Users can now organize and manipulate data in a variety of ways using all of MS® Excel tools. A number of templates are included.



video: MS® Excel Reports  

New Features in Version 11.1

Here are the highlighted features included with version 11.1.

enhancedsrtd

SRTD Display

Configurable annotations for resonances and updated SRTD table display

randomenh

Random Enhancements

Now includes weighted average control and downsampling of a breakpoint table

traces

Highlight Traces

Highlight a selected trace easily by clicking on a line or legend


complete list

Complete List

Check out the other version 11.1 enhancements





Sine Resonance Track & Dwell Display



Up to 20 user-defined resonant frequencies can now be displayed along with a new amplitude vs phase plot. One click report printing, phase tracking and resonance selection parameters are all within an easy-to-use test window.


video: new SRTD display feature 


Random Control Enhancements



We've now added a weighted-average control method for our random vibration test module. This is in addition to maximum, minimum, average and open-loop methods.

video: Random control weighting  

random weighting photo: Random control setup

The assigned weight is relative, so as an example: assigning a value of 3 for Ch 1 and a value of 1 for Ch 3, the weighted average for Ch1 = 75% and Ch3 = 25% of the total.


Highlight Graph Traces



Our new "highlighted traces" tool makes it easier to find the channel trace you're looking for by highlighting that trace for a second. You can use this tool by either clicking the trace directly on the graph or inside the channel legend. Watch the video for a demonstration.




video: Highlight traces on a graph  


New Features in Version 11.2

Here are the highlighted features included with version 11.2.

enhancedsrtd1

SRTD Graphing

Resonance display based on the current channel selection, and new hotkey for viewing resonances from stored data

test sequencer

Test Sequencer Update

Global folders now hold all of your data and reports when mixing test modes (sine, random, shock etc)



thd

THD

New graphs to display THD % across frequency or time in Sine mode


complete list 2

Complete List

Check out the other version 11.2 enhancements





back to top

srtd graphing examplephoto: SRTD graphing example

Sine Resonance Track & Dwell Graphing




Users can now view resonance tables from stored data files by opening the data file and pressing hotkeys Ctrl+T. From there the user can generate reports and tweak parameters for analysis at any time.


Test Sequencer Update



Run different test types in sequence (sine, random, shock etc) without any user . Now test sequencer includes the option to store everything in a single folder location for easy data and report retrieval.

video: new test sequencer features  


THD - New Analysis Tool in Sine Testing




Our new THD measurement graph in sine testing allows users to evaluate the total harmonic distortion of a system under vibration. This includes the shaker armature, head expander, fixture or product. Take a snapshot of your THD often to analyze changes in a system over time.




video: Swept THD analysis  


New Features in Version 11.3

Here are the highlighted features included with version 11.3.

support tools

Additional Support Tools

New support tools including notifications when network cable is unplugged, evaluation data for recent test support, and more.

analysis tools

Additional Analysis Tools

Random import with file statistics when viewing VFW files, improved waveform displays in FDR, and more.



graphing improve

More Graph Improvements

New options for graph settings, legends and traces.


complete list 3

Complete List

Check out the other version 11.3 enhancements including scheduling enhancemnets, improved safety features & more!





New Support Tools



New support tools have been added to provide more details on network communications as well as a new abort file that caches data to give a more complete analysis of any potential issues.


video: new support tools 


More Analysis Tools



We've now added a weighted-average control method for our random vibration test module. This is in addition to maximum, minimum, average and open-loop methods.

video: Random control weighting  

random control setup

photo: Random control setup

The assigned weight is relative, so as an example: assigning a value of 3 for Ch 1 and a value of 1 for Ch 3, the weighted average for Ch1 = 75% and Ch3 = 25% of the total.


Even Better Graphing features



Our new "highlighted traces" tool makes it easier to find the channel trace you're looking for by highlighting that trace for a second. You can use this tool by either clicking the trace directly on the graph or inside the channel legend. Watch the video for a demonstration.




video: Highlight traces on a graph  


contact